Suunto Cobra2 User Manual Page 44

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 43
9. TECHNICAL DATA
9.1. Technical specifications
Dimensions and weight:
Diameter: width 73 mm/2.85 in, length 165 mm/6.50 in
Thickness: 35 mm/1.40 in
Weight: 210 g/7.4 oz (without hose)
Depth gauge:
Temperature compensated pressure sensor
Salt water calibrated, in fresh water the readings are about 3% smaller (calibrated in
compliance with EN 13319)
Maximum depth of operation: 100 m/328 ft (complying with EN 13319)
Accuracy: ± 1% of full scale or better from 0 to 80 m/262 ft at 20°C/68°F (complying
with EN 13319)
Depth display range: 0 to 150 m/492 ft
Resolution: 0.1 m from 0 to 100 m/1 ft from 0 to 328 ft
Temperature display:
Resolution: 1°C/1°F
Display range: -20 to +50°C/-9 to +122°F
Accuracy: ± 2°C/± 3.6°F within 20 minutes of temperature change
Calendar clock:
Accuracy: ± 25 s/month (at 20°C/68°F)
12/24 h display
Displays only in NITROX mode:
Oxygen %: 21 - 99
Oxygen partial pressure display: 0.2 - 3.0 bar, depending on the limit setting
Oxygen Limit Fraction: 1 - 200% with 1% resolution
Logbook/dive profile memory:
Recording interval: 20 seconds adjustable (1,10,20,30,60s).
Memory capacity: approximately 42 hours of diving with 20 second recording interval
Depth accuracy: 0.3 m/1 ft
Operating conditions:
Normal altitude range: 0 to 3,000 m/10,000 ft above sea level
Operating temperature: 0°C to 40°C/32°F to 104°F
Storage temperature: -20°C to +50°C/ -4°F to +122°F
It is recommended that the instrument be stored in a dry place at room temperature.
NOTE
Do not leave the dive computer in direct sunlight!
Tissue calculation model:
Suunto Deep Stop RGBM algorithm (developed by Suunto and Bruce R. Wienke, BSc,
MSc, PhD)
9 tissue compartments
Tissue compartment halftimes: 2.5, 5, 10, 20, 40, 80, 120, 240 and 480 minutes (on
gassing). The off gassing halftimes are slowed down
Reduced gradient (variable) "M" values based on diving habit and dive violations. The
"M" values are tracked up to 100 hours after a dive
The EAN and oxygen exposure calculations are based on recommendations by R.W.
Hamilton, PhD and currently accepted exposure time limit tables and principles
Battery:
One 3 V lithium battery: CR 2450
Battery storage time (shelf life): Up to three years
Replacement: Every three years, or more often depending on dive activity
44
Page view 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 55 56

Comments to this Manuals