Suunto Vyper User Manual Page 70

  • Download
  • Add to my manuals
  • Print
  • Page
    / 86
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 69
68
Displays only in NITROX Mode:
Oxygen%: 21 - 50
Oxygen partial pressure display: 1.2 - 1.6 bar depending on the limit
setting
Oxygen Limit Fraction: 1 - 110% with 10% resolution (bar graph)
Logbook/Dive Pro le Memory:
Recording interval: 20 seconds (the recording interval can be set to 10s,
30s or 60s with the optional PC-interface and its software), records the
maximum depth of each interval.
Memory capacity: approximately 36 hours of diving with 20 seconds
recording interval
Depth accuracy: 0.3 m [1 ft]
Operating Conditions
Normal altitude range: 0 to 3000 m [10000 ft] above sea level
Operating temperature: 0°C to 40°C [32°F to 104°F]
Storage temperature: -20°C to +50°C [-4°F to +122°F]
It is recommended that the instrument be stored in a dry place at room
temperature.
NOTE! Do not leave the dive computer in direct sunlight!
Tissue Calculation Model
SUUNTO RGBM algorithm (developed by SUUNTO and Bruce R.
Wienke, BS, MS and PhD)
9 tissue compartments
Tissue compartment halftimes: 2.5, 5, 10, 20, 40, 80, 120, 240 and 480
minutes (on gassing). The off gassing halftimes are slowed down
Reduced gradient (variable) “M” values based on diving habit and dive
violations. The “M” values are tracked up to 100 hours after a dive
The EAN and oxygen exposure calculations are based on recommenda-
tions by R.W. Hamilton, PhD and currently accepted exposure time
limit tables and principles